Our Products

Product Range

8_378192182
The PSU-Series is a single output programmable switching DC power supply covering a power range up to 1520W. This Series of products include five models with the combination from 6V to 60V rated voltages. As th ePSU-series can be connected in series for maximum 2 units or in parallel for maximum 4 u ...Read more
GW Instek - PSU-Series Programmable Switching D.C. Power Supply

Features

  • Voltage Rating:6V/12.5V/20V/40V/60V
  • Output Power Rating: 1200W~1520W
  • C.V / C.C Priority ; Particularly Suitable for the Batterey & LED
  • industry
  • Adjustable Slew Rate
  • Series and Parallel operation (2 Units in Series or 4 units in
  • parallel)
  • High Efficiency and High Power Density
  • 19 Inch Rack Mount Size Design
  • Standard Interface: LAN, RS-232 & RS-485, USB(Device / Host), Analog
  • Control Interface



  • Details
  • Specifications

The PSU-Series is a single output programmable switching DC power supply covering a power range up to 1520W. This Series of products include five models with the combination from 6V to 60V rated voltages. As th ePSU-series can be connected in series for maximum 2 units or in parallel for maximum 4 units, capacity of connecting multiple PSU-Series units for higher voltage or higher current output provides a broad coverage of applications.

PSU-Series Specifications

The specifications apply when the PSU-Series is powered on for at least 30 minutes under +20°C~+30°C.

 

Output       

Model

 

PSU

6-200

12.5-120

20-76

40-38

60-25

Rated Output Voltage (*1)

 

V

6

12.5

20

40

60

Rated Output Current (*2)

 

A

200

120

76

38

25

 Rated Output Power

 

W

1200

1500

1520

1520

1500

Constant Voltage Mode       

Model

 

PSU

6-200

12.5-120

20-76

40-38

60-25

Line regulation (*3)

 

mV

2.6

3.25

4

6

8

Load regulation (*4)

 

mV

2.6

3.25

4

6

8

Ripple and noise (*5)

p-p (*6)

mV

60

60

60

60

60

 

r.m.s. (*7)

mV

8

8

8

8

8

Temperature coefficient

 

ppm/ °C

100ppm/°C of rated  output voltage, after a 30 minute warm-up.

Remote sense compensation voltage (single wire)

 

V

1

1

1

2

3

Rise time (*8)

Rated load

ms

80

80

80

80

80

 

No load

ms

80

80

80

80

80

Fall time (*9)

Rated load 

ms

10

50

50

80

80

 

No load

ms

500

700

800

1000

1100

Transient response time (*10)

 

ms

1.5

1

1

1

1

Constant Current Mode       

Model

 

PSU

6-200

12.5-120

20-76

40-38

60-25

 Line regulation (*3)

 

mA

22

14

9.6

5.8

4.5

Load regulation (*11)

 

mA

45

29

20.2

12.6

10

Ripple and noise (*12)

r.m.s.

mA

400

240

152

95

75

Temperature coefficient

 

ppm/ °C

100ppm/°C of rated  output voltage, after a 30 minute warm-up.

Protection Function       

Model

 

PSU

6-200

12.5-120

20-76

40-38

60-25

Over voltage protection (OVP)

Setting range

V

0.6-6.6

1.25-13.75

2-22 

4-44

5-66

 

Setting accuracy

V

0.06

0.125

0.2

0.4

0.6

Over current protection (OCP)

Setting range

A

5-220

5-132

5-83.6

3.8-41.8

2.5-27.5

 

Setting accuracy

A

4

2.4

1.52

0.76

0.5

Under voltage limit (UVL)

Setting range

 

0-6.3

0-13.12

0-21

0-42

0-63

Over temperature protection (OHP)

Operation

 

Turn the output off.

Incorrect sensing connection protection (SENSE)

Operation

 

Turn the output off.

Low AC input protection (AC-FAIL)

Operation

 

Turn the output off.

Shutdown (SD)

Operation

 

Turn the output off.

Power limit (POWER LIMIT)

Operation

 

Over power limit.

 

Value (fixed)

 

Approx. 105% of rated output power    

Analog Programming and Monitoring       

Model

 

PSU

6-200

12.5-120

20-76

40-38

60-25

External voltage control output voltage

 

 

Turn the output off.

External voltage control output current

 

 

Turn the output off.

External resistor control output voltage

 

 

Turn the output off.

External resistor control output current

 

 

Turn the output off.

Output voltage monitor

 

 

Turn the output off.

Output current monitor

 

 

Turn the output off.

Shutdown control

 

 

Turns the output off with a LOW (0V to 0.5V) or short-circuit.

Output on/off control

 

 

Possible logic selections:
Turn the output on using a LOW (0V to 0.5V) or short-circuit, turn the output off using a HIGH (4.5V to 5V) or open-circuit
Turn the output on using a HIGH (4.5V to 5V) or open-circuit, turn the output off using a LOW (0V to 0.5V) or short-circuit.

Alarm clear control

 

 

Clear alarms with a LOW (0V to 0.5V) or short-circuit.

CV/CC/ALM/PWR ON/OUT ON indicator

 

 

Photocoupler open collector output; Maximum voltage 30V, maximum sink current 8mA.

Trigger out

 

 

Maximum low level output = 0.8V; minimum high level output = 2V; Maximum source current = 8mA.

Trigger in

 

 

Maximum low level input voltage = 0.8V; minimum high level input votage = 2.0V, Maximum sink current = 8mA.

Front Panel       

Model

 

PSU

6-200

12.5-120

20-76

40-38

60-25

Display, 4 digits

 

 

 

 

 

 

 

Voltage accuracy

0.1% +

mV

12

25

40

80

120

Current accuracy

0.2% +

mA

600

360

228

114

75

Indications

 

 

GREEN LED's: CV, CC, V, A, VSR, ISR, DLY, RMT, LAN, M1, M2, M3, RUN, Output ON
RED LED's: ALM, ERR

Buttons

 

 

Lock/Local(Unlock), PROT(ALM_CLR), Function(M1), Test(M2), Set(M3), Shift, Output

Knobs

 

 

Voltage, Current

USB port

 

 

Type A USB connector

Programming and Measurement (RS-232/485, USB, LAN, GPIB)       

Model

 

PSU

6-200

12.5-120

20-76

40-38

60-25

Output voltage programming accuracy

0.05% +

mV

3

6.25

10

20

30

Output current programming accuracy

0.2% +

mA

200

120

76

38

25

Output voltage programming resolution

 

mV

0.2

0.4

0.7

1.3

2

Output current programming resolution

 

mA

6

4

2.5

1.2

0.8

Output voltage measurement accuracy

0.1% +

mV

6

12.5

20

40

60

Output current measurement accuracy

0.2% +

mA

400

240

152

76

50

Output voltage measurement resolution

 

mV

0.2

0.4

0.7

1.3

2

Output current measurement resolution

 

mA

6

4

2.5

1.2

0.8

Input Characteristics       

Model

 

PSU

6-200

12.5-120

20-76

40-38

60-25

Norminal input rating

 

 

100Vac to 240Vac, 50Hz to 60Hz, single phase

Input voltage range

 

 

85Vac ~ 265Vac

Input frequency range

 

 

47Hz ~ 63Hz

Maximum input current

100Vac

A

21

 

200Vac

A

11

Inrush current

 

 

Less than 50A.

Maximum input power

 

VA

2000

Power factor

100Vac

 

0.99

 

200Vac

 

0.98

Efficiency (*13)

100Vac

 

77

82

83

84

84

 

200Vac

 

79

85

86

87

87

Hold-up time

 

 

20ms or greater

Interface Capabilities       

Model

 

PSU

6-200

12.5-120

20-76

40-38

60-25

USB

 

 

TypeA: Host, TypeB: Slave, Speed: 1.1/2.0, USB Class: CDC(Communications Device Class)

LAN

 

 

MAC Address, DNS IP Address, User Password, Gateway IP Address, Instrument IP Address, Subnet Mask

GPIB

 

 

SCPI - 1993, IEEE 488.2 compliant interface

RS-232/RS-485

 

 

Complies with EIA232D / EIA485 Specifications

Environment Conditions       

Model

 

PSU

6-200

12.5-120

20-76

40-38

60-25

Operating temperature

 

 

0˚C to 50˚C

Storage temperature

 

 

-25˚C to 70˚C

Operating humidity

 

 

20% to 85% RH; No condensation

Storage humidity

 

 

90% RH or less; No condensation

Altitude

 

 

Maximum 2000m

Environment Conditions       

Model

 

PSU

6-200

12.5-120

20-76

40-38

60-25

Weight

main unit only

kg

Less than 8.7kg

Dimensions

(W×H×D)

mm3

423×43.6×447.2

Cooling

 

 

Forced air cooling by internal fan.

EMC

 

 

Complies with the European EMC directive 2004 /108/EC for Class A test and measurement products.

Safety

 

 

Complies with the European Low Voltage Directive 2006 /95/EC and carries the CE-marking.

Withstand voltage

 

 

AC to Chassis: 1500Vac/1min
AC to Output terminal: 3000Vac/1min
Output terminal to Chassis: 1000Vdc/1min

Insulation resistance

 

 

Chassis and output terminal; chassis and AC input; AC input and output terminal: 100MΩ or more (DC 500V)

 

 

 

 

 

 

 

 

Image

Contact Info

Headquarters
963, Jalan Perusahaan, Kawasan Perindustrian Prai, 13600 Prai, Pulau Pinang, Malaysia.
Our Offices
Malaysia | Thailand | Singapore-Indonesia | Vietnam | Philippines

Register Form

Cancel

Sign in to your account

Register Form

Cancel

Sign in to your account