963, Jalan Perusahaan, Kawasan Perindustrian Prai, 13600 Prai, Pulau Pinang, Malaysia.
Malaysia | Thailand | Singapore-Indonesia | Vietnam | Philippines
The GDS-3000 Series is a platform of 4-input channels, 500MHz bandwidth, 5GSa/s sampling rate, and VPO waveform display. The split screen feature has been designed to meet the requirements of multi-window & multi-signal tests in the research and the manufacturing fields. The optional power analysis software and the optional serial bus analysis software are available to facilitate the engineer's tasks in testing and manufacturing of the associated products.
The differential probe, GDP-025, GDP-050 & GDP-100, and current probes, GCP-020, GCP-100 and GCP-530 & GCP-1030, are coming along with the GDS-3000 Series to provide total solutions for a wide variety of applications in the industry, service and education market sectors. The GDS-3000 Series, a high-tech platform carrying thoughtful features, brings very high customer value to both general purpose market and professional market.
GDS-3000 Specifications
The specifications apply when the GDS-3000 is powered on for at least 30 minutes under +20°C~+30°C.
Model-specific
GDS-3152 |
Channels |
2 + Ext |
Bandwidth |
DC ~ 150MHz (–3dB) |
|
Rise time |
2.3ns |
|
GDS-3154 |
Channels |
4 + Ext |
Bandwidth |
DC ~ 150MHz (–3dB) |
|
Rise time |
2.3ns |
|
GDS-3252 |
Channels |
2 + Ext |
Bandwidth |
DC ~ 250MHz (–3dB) |
|
Rise time |
1.4ns |
|
GDS-3254 |
Channels |
4 + Ext |
Bandwidth |
DC ~ 250MHz (–3dB) |
|
Rise time |
1.4ns |
|
GDS-3352 |
Channels |
2 + Ext |
Bandwidth |
DC ~ 350MHz (–3dB) |
|
Rise time |
1ns |
|
GDS-3354 |
Channels |
4 + Ext |
Bandwidth |
DC ~ 350MHz (–3dB) |
|
Rise time |
1ns |
|
GDS-3502 |
Channels |
2 + Ext |
Bandwidth |
DC ~ 500MHz (–3dB) |
|
Rise time |
700ps |
|
GDS-3504 |
Channels |
4 + Ext |
Bandwidth |
DC ~ 500MHz (–3dB) |
|
Rise time |
700ps |
|
The bandwidth of the 75Ω input impedance is limited to 150MHz only. |
Common
Vertical |
Resolution Sensitivity |
8 bit @1MΩ: 2mV~5V/div @50/75Ω: 2mV~1V/div |
Input Coupling |
AC, DC, GND |
|
Input Impedance |
1MΩ// 15pF |
|
DC Gain Accuracy |
±3% full scale |
|
Polarity |
Normal & Invert |
|
Maximum Input Voltage |
@1 MΩ: 300Vrms, CAT I @50/75Ω: 5 Vrms max |
|
Offset Position Range |
2mV/div ~ 100mV/div : ±0.5V 200mV/div ~ 5V/div : ±25V |
|
Bandwidth Limit |
Dependent on the oscilloscope bandwidth (BW. BW=150: Full/20MHz BW=250: Full/20MHz/100MHz BW=350: Full/20MHz/100MHz/200MHz |
|
Waveform Signal Process |
Add, subtract, multiply, and divide waveforms, FFT, FFTrms, Integration*, Differentiation* |
|
FFT:Spectral magnitude. Set FFT Vertical Scale to Linear RMS or dBV RMS, and FFT Window to Rectangular, Hamming, Hanning, or Blackman-Harris. |
||
Trigger |
Sources |
CH1, CH2, CH3, CH4, Line, EXT |
Modes |
Auto (supports Roll Mode for 100 ms/div and slower), Normal, Single Sequence |
|
Type |
Edge, Pulse Width(Glitch), Video, Pulse Runt, Rise & Fall(Slope), Alternate, Event-Delay(1~65535 events), Time-Delay(Duration)(10ns~10s), I2C*, SPI*, UART* *optional |
|
Runt:Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again. |
||
SPI (optional):Trigger on SS, MOSI, MISO, or MOSI and MISO on SPI buses. |
||
I2C (optional):Trigger on Start, Repeated Start, Stop, Missing ACK, Address (7 or 10 bit), Data, or Address and Data on I2C buses. |
||
UART (optional): Trigger on Tx Start Bit, Rx Start Bit, Tx End of Packet, Rx End of Packet, Tx Data, Rx Data, Tx Parity Error, and Rx Parity Error. |
||
Holdoff range |
10ns to 10s |
|
Coupling |
AC, DC, LF rej., Hf rej., Noise rej. |
|
Sensitivity |
GDS-31XX ~ GDS-33XX: 50MHz ~ 150MHz Approx. 1.5div or 15mV 150MHz ~ 350MHz Approx. 2div or 20mV GDS-350X: DC ~ 50MHz Approx. 1div or 1.0mV 50MHz ~ 150MHz Approx. 1.5div or 15mV 150MHz ~ 350MHz Approx. 2div or 20mV 350MHz ~ 500MHz Approx. 2.5div or 25mV |
|
External Trigger |
Range |
±15V |
Sensitivity |
GDS-31XX ~ GDS-33XX: DC ~ 150MHz Approx. 100mV 150MHz ~ 250MHz Approx. 150mV 350MHz ~ 500MHz Approx. 200mV |
|
Input Impedance |
1MΩ±3%, ~16pF |
|
Horizontal |
Timebase Range |
GDS-31XX, GDS-32XX, GDS-33XX: GDS-350X: |
Pre-trigger |
10 div maximum |
|
Post-trigger |
1000 div maximum. The number of divisions depends on the time division. |
|
Timebase Accuracy |
±20 ppm over any ≧1 ms time interval |
|
X-Y Mode |
X-Axis Input |
Channel 1; Channel 3 |
Y-Axis Input |
Channel 2; Channel 4 |
|
Phase Shift |
±3° at 100kHz |
|
Signal Acquisition |
Real Time Sample Rate |
150/250/300MHz models: 5GSa/s (MAX) 500MHz models: 4GSa/s (MAX), 2GSa/s per channel |
ET Sample Rate |
100GSa/s maximum for all models |
|
Record Length |
25k points / channel |
|
Acquisition Mode |
Normal, Average, Peak Detect, High Resolution, Single Sequence |
|
Peak (Glitch) Detection |
2ns (MAX) |
|
Normal: Acquire sampled values. Average: From 2 to 256 waveforms included in average. Peak Detect: Captures glitches as narrow as 2 ns at all sweep speeds Hi Res: Real-time boxcar averaging reduces random noise and increases vertical resolution |
||
Cursors and Measurement |
Cursors |
Amplitude, Time, Gating available |
Automatic Measurement |
28 sets: Vpp, Vamp, Vavg, Vrms, Vhi, Vlo, Vmax, Vmin, Rise Preshoot/Overshoot, Fall Preshoot/Overshoot, Freq, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle, and nine different delay measurements (FRR, FRF, FFR, FFF, LRR, LRF, LFR, LFF, Phase) |
|
Cursors measurement |
Voltage difference between cursors ( ∆V) Time difference between cursors ( ∆T) |
|
Auto counter |
6 digits, range from 2Hz minimum to the rated bandwidth |
|
Power Measurements (Option) |
Power Quality Measurements |
V RMS, I RMS, True Power, Apparent Power, Reactive Power, Frequency, Power Factor, Phase Angle, V Crest Factor, I Crest Factor, (+)V Peak, |
Harmonics |
Frequency (Hz), Magnitude (%), Mag. RMS (A), Phase (˚), Limit (A), Limit (%), Pass | Fail, Max all , Windows (A), 200% Limit, POHC Limit, THD-F, THD-R, RMS, Overall, POHC, POHL, Input Power, Power Factor, Fundamental Current, Harmonic 3, Harmonic 5 |
|
Ripple Measurements |
Ripple, Noise |
|
In-rush current |
First peak, Second peak |
|
Control Panel Function |
Autoset |
Single-button, automatic setup of all channels for vertical, horizontal and trigger systems, with undo autoset |
Auto-Range |
allow you to quickly move from test point to test point without having to reset the oscilloscope for each test point |
|
Save Setup |
20 sets |
|
Save Waveform |
24 sets |
|
Display |
TFT LCD Type |
8" TFT LCD SVGA color display |
Display Mode |
YT, XY |
|
Display Resolution |
800 horizontal × 600 vertical pixels (SVGA) |
|
Interpolation |
Sin(x)/x & Equivalent Time Sampling |
|
Waveform Display |
Dots, vectors, variable persistence, infinite persistence |
|
Display Graticule |
8 x 10 divisions |
|
Waveform Update Rate |
3500 waveforms per second maximum |
|
Interface |
RS232C |
DB-9 male connector |
USB Port |
2 sets USB 2.0 High-speed host port 1 set USB High-speed 2.0 device port |
|
Ethernet Port (LAN) |
RJ-45 connector, 10/100Mbps |
|
SVGA Video Port |
DB-15 female connector, monitor output for display on SVGA monitors |
|
GPIB |
GPIB to USB adapter (Option) |
|
Go-NoGo BNC |
5V Max, 10mA CMOS open collector output |
|
Internal flash disk |
64MB |
|
Kensington Style Lock |
Rear-panel security slot connects to standard Kensington-style lock. |
|
Line output |
3.5mm stereo jack for Go/NoGo audio alarm |
|
Power Source |
Line Voltage Range |
AC 100V ~ 240V , 48Hz ~ 63Hz , Auto selection |
Power Consumption |
96VA |
|
Miscellaneous |
Multi-language menu |
Available |
On-line help |
Available |
|
Time clock |
Time and Date ,Provide the Date/Time for saved data |
|
Dimensions |
400W X 200H X 130D, Approx. 4kg |
Probe Specifications
Model-specific Probe Specifications
GTP-151R |
Applicable to |
GDS-3152 / GDS-3154 |
Bandwidth |
DC ~ 150MHz |
|
Rise time |
2.3ns |
|
Input Capacitance |
~12pF |
|
Compensation Range |
10 ~ 30pF |
|
GTP-251R |
Applicable to |
GDS-3252 / GDS-3254 |
Bandwidth |
DC ~ 250MHz |
|
Rise time |
1.4ns |
|
Input Capacitance |
~12pF |
|
Compensation Range |
10 ~ 30pF |
|
GTP-351R |
Applicable to |
GDS-3352 / GDS-3354 |
Bandwidth |
DC ~ 350MHz |
|
Rise time |
1.0ns |
|
Input Capacitance |
~12pF |
|
Compensation Range |
10 ~ 30pF |
|
GTP-501R |
Applicable to |
GDS-3502 / GDS-3504 |
Bandwidth |
DC ~ 500MHz |
|
Rise time |
0.7ns |
|
Input Capacitance |
~11.5pF @ 100MHz |
|
Compensation Range |
8 ~ 20pF |
Common Probe Specifications
Position x 10 |
Attenuation Ratio |
10:1 (fixed) with readout pin |
Input Resistance |
10MΩ when used with 1MΩ input oscilloscope |
|
Maximum Input Voltage |
500V CAT I, 300V CAT II derating with frequency |
|
Operating Condition |
Temperature |
–0°C ~ 50°C |
Relative Humidity |
≤85% @35°C |
|
Safety Standard |
EN61010-031 CAT II |